Prof. Jean Marc Sene, PhD (Centre National des Sports de la
Défense Fontainebleau - France)
PROPOSITION OF
STANDARDS FOR MEASURE ON STABILOMETRIC PLATFORM AFP
40/16
|
|
PROPOSITION OF STANDARDS FOR MEASURE ON STABILOMETRIC PLATFORM AFP 40/16
SENE, JEAN MARC
Centre National des Sports de la Défense – Fontainebleau - France
The objective of our work was to compare the values of the " standards 85 ", validated on
stabilométric platform 5hz with those obtained by a platform AFP 40/16.
A group of 45 subjects with an high-level of sport practice participated in the measures. Those
subjects were 25,5 years old + 6,3, 1,76 m + 0,1, 73,1 kg +8,8 practising of the sports varied 22,1
hours / week + 8,7. A stabilométric platform Satel ® was used. The protocol of the stabilométric
measures was realized in static condition, opened then closed eyes, alternately on hard ground then
soft ground. The data processing concerned the parameters of performance: surface, LFS, Xmeans and
There Means.
Paramètre sol dur |
Normes 85 YO |
YO |
Normes 85 YF |
YF |
X-mean |
1.1 (-9.6/11.7) |
-1.1 (-13.9/11.7)* |
0.3 (-10.5/11.1) |
-0.03 (-15.2/15.2)* |
Y-mean |
-29.2 (-1.5/-57) |
-39.1 (6.5/-84.7)* |
-27.5 (-3.6/-51.4) |
-36.9 (5.7/-79.5)* |
Surface |
91 (39/210) |
137 (5/269)* |
225 (79/638) |
225 (0/501)* |
LFS |
1 (0.82/1.39) |
0.96 (0.52/1.4)* |
1 (0.70/1.44) |
1.1 (0.5/1.7)* |
* No significant difference with " standard 85 "
Paramètre sol mou |
YO |
YF |
X-mean |
-2.6 (-20.9/15.7) |
-1.1 (-20.7/18.5) |
Y-mean |
-9.7 (-55.1/35.7) |
-4.6 (-50/40.8) |
Surface |
458 (130/786) |
1723 (387/3059) |
LFS |
1.8 (1.2/2.4) |
1.3 (03/2.3) |
Discussions and conclusions: the " standards 85 " seem valid for platforms AFP 40/16 on hard ground.
We propose besides new standards on soft ground. Limits of standards more tightened for our sports
population seem necessary as well as to widen the processing of data raised in particular in
frequency analysis ad in dynamic condition measures.
|